EST Scanner Functions


  • Programmable hipot output voltage to 5kV AC and 6kV DC
  • Trip current programmable to 30mA AC and 10mA DC
  • Insulation resistance to 50GΩ / 5KV DC
  • DCR 10mΩ ~ 100kΩ
  • Built-in 8 channel scanner
  • Storage of 20 tests setups with 50 steps per setup

Key Features


  • Open/Short check (OSC) function to ensure of DUT connection
  • SUB-STEP function
  • GFI Human protection - shutdown if current imbalance >0.5mA
  • DWX Series - Impulse Winding Tester compatable
  • Flashover detection
  • Key Lock function
  • RS232 Interface (standard)
  • GPIB & Handler (optional)
  • Friendly interface
  • CE Mark

Applications

The 19035 is a comprehensive tester designed for wound component safety and design verification testing requirements.

  • Motor, Fan: 19035-M / 19035-ML
  • Electric Heater Tube: 19035-M / 19035-ML
  • Transformer: 19035/ 19035-L
  • Switch, Wire: 19035 / 19035L
  • Camera Micro Motor, Coil: 19035-S

Information

» 949 600 6400
» email sales
» email service
» Datasheet
» Comparative Data


See Other Safety Equipment



twitterGet our Newsletter: Click the link below to register.

Sign me up!

 

Follow Us


Facebook - Chroma Systems SolutionsTwitter - Chroma Systems SolutionsRSS - Chroma Systems Solutions

 

 

 

 

 

Wound Component EST Scanner - 19035

Chroma's 19035 Wound Component Scanner is a production safety tester designed for test requirements of three-phase motors, double-wound transformers and heater related wound components. Quality verification test items for wound components consist of AC/DC Hipot (dielectric withstanding), Insulation Resistance (IR), and Impulse Winding tests. We have integrated these tests into one unit.

Hipot, IR, and Impulse Winding Test

19035 AC/DC Hipot, IR, DCR
CE Mark

The 19035 is designed to directly connect to a DWX Series Impulse Winding Tester and use the 8-Channel scanning capabilities to reach multiple points in one test instead of switching test points manually.

See Specs

   

 

Ordering information


19035: Wound Component EST Scanner
19035-M: Wound Component EST Scanner
19035-ML: Wound Component EST Scanner
19035-L: Wound Component EST Scanner
19035-S: Wound Component EST Scanner
A190345: High voltage cable for Impulse Winding Tester connection
A190346: RS-232 cable for Impulse Winding Tester connection

A190347: GPIB, Handler & Temperature interface
A190348: RS-232 Interface
A190351: 8ch-16ch HV box for 19035
A190352: Wound Componenet pneumantic scan box
A190354: Dual switch fixture for A190352
A190702: 40kV HV Test probe

 

Specifications


Model 19035 19035-L 19035-M 19035-ML 19035-S
Mode AC/DC/IR/
DCR -8CH/ IWT
AC/DC/IR/ DCR -8CH/ IWT AC/DC/IR/
DCR -16CH/ IWT
AC/DC/IR/
DCR -16CH/ IWT
AC/DCR -8CH
Impulse Winding Test
(Layer Short, IWT)
External option Internal standard External option Internal standard -
Channel Programming H/L/X in 8CHs H/L/X in 8CHs H/X in CH 1,2,3,5,6,7
L/X in CH 4,8
H/X in CH 1,2,3,5,6,7
L/X in CH 4,8
H/L/X in 8CHs
Withstanding Voltage Test
Output Voltage

AC: 0.05~5KV / DC: 0.05~6KV

Load Regulation ±(1% setting + 0.1%full Scale)
Voltage Regulation 2V
Voltage Accuracy 1% setting + 0.1% full Scale
Cutoff Current

AC: 30mA / DC: 10mA

Current Resolution AC: 1µA / DC: 0.1µA
Current Accuracy 1% of reading + 0.5% of range (1% of reading + 5% of total current)
Current Frequency 50Hz / 60Hz
Test Time 0.1 ~ 999 sec , continue
Test / Ramp / Fall / Dwell Time 0.3 ~ 999 sec., continue / 0.1 ~ 999 sec., off / 0.1 ~ 999 sec., off / 0.1 ~ 999 sec., off
Wave Form Sine wave
Insulation Resistance Test
Output Voltage DC : 0.05 ~ 5kV
Voltage Resolution 2V
Voltage Accuracy 1% of setting + 0.1% of full range
IR Range 1MΩ ~ 50GΩ
Resistance Resolution 0.1MΩ
Resistance Accuracy ≧1000V 0.1MΩ ~ 1GΩ : ± (3% of reading + 0.1% of full range)
1GΩ ~ 10GΩ : ± (7% of reading + 2% of full range)
10GΩ ~ 50GΩ : ± (10% of reading + 1% of full range)
500V~1000V 0.1MΩ ~ 1GΩ : ± (3% of reading + 0.1% of full range)
1GΩ ~ 10GΩ : ± (7% of reading + 2% of full range)
10GΩ ~ 50GΩ : ± (10% of reading + 1% of full range)
≦500V 0.1MΩ ~ 1GΩ : ± 3% of reading + (0.2*500/Vs)% of full scale
DC Resistance Measurement
Test Signal <DC 10V. < DC 100mA
Measurement mode 2 terminals (2W) / 4 terminals(4W) measurement selectable
Measurement Accuracy
(2W/ 4W)
1Ω (4W only) ±(0.5% of reading + 0.5% of range)
10kΩ ± (2% of reading + 0.5% of range) / ± (0.5% of reading + 0.05% of range)
100kΩ
1kΩ
10kΩ
100kΩ
Flashover Detection
Setting Mode Programmable setting
Detection Current AC : 1mA ~ 15mA, DC : 1mA ~ 10mA
Secure Protection Function
Fast Output Cut-off 0.4ms after NG happen
Ground Fault Interrupt
0.5mA ±0.25mA AC, ON/OFF
Panel Operation Lock Present password
Interlock YES
GO/NG Judgment Window
Indication, Alarm
GO : Short sound, Green LED; NG : Long sound, Red LED
Data Hold Least tests data memories
Memory Storage 50 instrument setups with up to 20 test steps
Interface
RS232*1 (Standard), RS232*1 or GPIB & Handler & Temperature interface (Optional).
General
Operation Environment Temperature : 0°C~45°C, Humidity : 15% to 95% R.H@≦40°C
Power Consumption 500VA
Power Requirements 90~132Vac or 198~264Vac, 47~66Hz
Weight Approx. 20KG
Certifications CE Mark

*All specifications subject to change without notice.